STRATOS-Z


STRATOS-Z

Design

Glandless circulating pump with screwed connection or flange connection, EC motor and automatic power adjustment.

Application

Secondary hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems


 
Type key
Example Wilo-Stratos-Z 40/1-8
Stratos High-efficiency pump (screw-end or flange-end pump), electronically controlled
Z Single pump for secondary hot water circulation
40/ Nominal connection diameter
1-8 Nominal delivery head range [m]


Special Features/Product Advantages

  • Maximum efficiency thanks to ECM technology
  • Front operation and access to terminal room, variable installation positions, display independent of position
  • Simple installation due to PN 6/PN 10 combination flanges (with DN 40 to DN 65)
  • Corrosion-resistant pump housing made of red brass for systems where oxygen entry is possible
  • Automatic adjustment of the pump output in volume-flow-variable secondary hot water circulation systems with thermostatically controlling line shut-off valves
  • Manual control mode allows optimum adaptation of the pump output to the system in constant-volume secondary hot water circulation systems
  • System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, LON, CAN, PLR etc.
  • Remote control via infrared interface (IR stick/IR monitor)


Technical Data

  • Permissible temperature range
    • Potable water up to 3.57 mmol/l (20 °dH): 0 °C to +80 °C
    • Heating water: -10 °C to +110 °C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IPX4D
  • Screwed connection or flange connection (depending on type) Rp 1 to DN 65
  • Max. operating pressure, standard version: 6/10 bar (special version: 16 bar)




Equipment/Function



Operating Modes

  • Manual control mode (n=constant)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Δp-T for temperature-controlled differential pressure (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)


Manual Functions

  • Operating mode setting
  • Differential pressure setpoint setting
  • Setting automatic setback operation
  • Pump ON/OFF setting
  • Speed setting (manual control mode)


Automatic Functions

  • Variable power adjustment depending on the operating mode
  • Automatic setback operation
  • Deblocking function
  • Soft start
  • Full motor protection with integrated trip electronics


External Control Functions

  • "Overriding Off" control input (possible with Stratos IF-Modules)
  • "Overriding Min" control input (possible with Stratos IF-Modules)
  • "Analogue In 0 - 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)
  • "Analogue In 0 - 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)


Signal and Display Functions

  • Collective fault signal (potential-free NC contact)
  • Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)
  • Fault signal light
  • LC display for indication of pump data and fault codes


Data Exchange

  • Infrared interface for wireless data exchange with IR-Stick/IR-Monitor
  • Modbus RTU serial digital interface for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
  • BACnet serial digital interface MS/TP slave for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
  • CAN serial digital interface for connection to building automation BA via CAN BUS system (possible with Stratos IF-Modules)
  • LON serial digital interface for connection to a LONWorks network (possible with Stratos IF-Modules)
  • PLR serial digital interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)


Dual Pump Management (Double Pump or 2 x Single Pump)

  • Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations with Stratos IF-Modules (accessories) possible
  • Paralel operation (efficiency-optimised peak load activation and deactivation): various combinations with Stratos IF-Modules (accessories) possible


Equipment

  • Wrench attachment point on pump body (for threaded pipe union pumps with P2≤100 W)
  • For flange-end pumps: Flange versions
    • Standard version for DN 40 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges,
    • Special version for DN 40 to DN 65 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange,
  • Plug-in position for optional extension with Wilo-IF-Modules
  • Thermal insulation as standard


Materials

  • Pump housing made of red brass (30/1-12 and 40/1-8 types, also grey cast iron)
  • Impeller: Plastic
  • Shaft: stainless steel
  • Bearing: Carbon, synthetic resin impregnated


Scope of delivery

  • Pump
  • Including thermal insulation
  • Including seals for threaded connection (loose)
  • Including washers for flange screws (for nominal connection diameters DN 40 - DN 65)
  • Including installation and operating instructions


Options

  • Special versions for operating pressure PN 16


Accessories

  • Screwed connection for threaded connection
  • Adapter fittings
  • IR-Stick
  • IR-Monitor
  • Stratos IF-Modules: Modbus, BACnet, CAN, PLR, LON, DP, Ext. Off, Ext. Min., SBM, Ext. Off/SBM