NPG
Design
Single-stage low-pressure centrifugal pump mounted on the baseplate
Application
Pumping heating water in accordance with VDI 2035 water/glycol mixtures, cooling/cold water and secondary hot water
Applications in municipal water supply, irrigation, building services, general industry, power stations, etc.
Special features/product advantages
-
Suitable for temperatures up to 140°C
-
Back-pull-out version
-
Extension of the DIN EN 733 product range
Scope of delivery
-
Pump
-
Installation and operating instructions
Materials
-
Pump housing: EN-GJL-250
-
Impeller: EN-GJL-250
-
Shaft: depending on type X30Cr13
Description/design
Single-stage low-pressure centrifugal pump in block construction with coupling, coupling protection, motor and baseplate
-
Spacer coupling
-
Mechanical shaft seal or stuffing box
General notes - ErP (ecological design-) directive
- The benchmark for most efficient water pumps is MEI ≥ 0.70
- The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter. The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption. The minimum efficiency index (MEI) is based on the full impeller diameter.
- The operation of this water pump with variable duty points may be more efficient and economic when controlled, for example, by the use of a variable speed drive that matches the pump duty to the system.
- Information on benchmark efficiency is available at www.europump.org/efficiencycharts