TP-50-65
Design
Submersible sewage pump
Application
Pumping of heavily contaminated fluids for:
» Domestic and site drainage
» Sewage disposal (not within the scope of DIN EN 12050-1)
» Water management
» Environmental and water treatment technology
» Industrial and process engineering
|
Type key |
Example |
Wilo-Drain TP 65 E 114/11‐A |
TP |
Submersible pump |
65 |
Nominal diameter [mm] |
E |
Impeller shape (E = single-channel impeller, F = Vortex impeller) |
114 |
Nominal diameter of the impeller [mm] |
11 |
Power P2 [kW] (=value/10 = 1.1 kW) |
A |
With float switch and plug |
Special Features/Product Advantages
- Detachable connection cable
- Stainless-steel glanded motor
- ATEX approval (only for TP 65/3~ without floater)
- Attached float switch (A-model version) enables simple operation
- Low weight
- Motor housing optionally available in 1.4404
Technical data
- Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
- Immersed operating mode: S1
- Non-immersed operating mode: S2-8 min, S3 25%
- Protection class: IP 68
- Insulation class: F
- Thermal winding monitoring
- Max. fluid temperature: 3 - 35°C
- Cable length: 10 m
- Free ball passage: 44 mm
- Max. immersion depth: 10 m