STRATOS
Design
Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment.
Application
Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.
|
Type key |
Example |
Wilo-Stratos 30/1-12 |
Stratos |
High-efficiency pump (screw-end or flange-end pump), electronically controlled |
30/ |
Nominal connection diameter |
1-12 |
Nominal delivery head range [m] |
Special features/Product advantages
- Maximum efficiency due to ECM technology
- Front operation and access to terminal room, variable installation positions, display independent of position
- Simple installation due to PN 6/PN 10 combination flanges (with DN 32 to DN 65)
- Application possible in cooling/air-conditioning systems without ambient temperature limitation
- Pump housing with cataphoretic (KTL) coating to prevent corrosion due to condensation formation
- System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, CAN, LON, PLR etc.
- Remote control via infrared interface (IR stick/IR monitor)
Technical data
- Permissible temperature range ‐10 °C ilâ +110 °C
- Mains connection 1~230 V, 50/60 Hz
- Protection class IPX4D
- Screwed connection or flange connection (depending on type) Rp 1 to DN 100
- Max. operating pressure, standard version: 6/10 bar or 6 bar (special version: 10 bar or 16 bar)
Equipment/Function
Operating modes
- Manual control mode (n=constant)
- Δp-c for constant differential pressure
- Δp-v for variable differential pressure
- Δp-T for temperature-controlled differential pressure (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)
Manual functions
- Operating mode setting
- Differential pressure setpoint setting
- Setting automatic setback operation
- Pump ON/OFF setting
- Speed setting (manual control mode)
Automatic functions
- Variable power adjustment depending on the operating mode
- Automatic setback operation
- Deblocking function
- Soft start
- Full motor protection with integrated trip electronics
External control functions
- "Overriding Off" control input (possible with Stratos IF-Modules)
- "Overriding Min" control input (possible with Stratos IF-Modules)
- "Analogue In 0 - 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)
- "Analogue In 0 - 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)
Signal and display functions
- Collective fault signal (potential-free NC contact)
- Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)
- Fault signal light
- LC display for indication of pump data and fault codes
Data exchange
- Infrared interface for wireless data exchange with IR-Stick/IR-Monitor
- Modbus RTU serial digital interface for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
- BACnet serial digital interface MS/TP Slave for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
- CAN serial digital interface for connection to building automation BA via CAN BUS system (possible with Stratos IF-Modules)
- LON serial digital interface for connection to a LONWorks network (possible with Stratos IF-Modules)
- WPLR serial digital interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)
Dual pump management (double pump or 2 x single pump)
- Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations with Stratos IF-Modules (accessories) possible
- Parallel operation (efficiency-optimised peak load activation and deactivation): various combinations with Stratos IF-Modules (accessories) possible
Equipment
- Wrench attachment point at pump body (for threaded pipe union pumps with P2< 100 W)
- For flange-end pumps: Flange versions
- Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges
- Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
- Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange
- Plug-in position for optional extension with Wilo-IF-Modules
- Standard thermal insulation for heating applications
Materials
- Pump housing: Grey cast iron with cataphoretic coating
- Thermal insulation: Polypropylene
- Shaft: stainless steel
- Bearing: Carbon, metal impregnated
- Impeller: Plastic
Scope of delivery
- Pump
- Including thermal insulation
- Including seals for threaded connection
- Incl. washers for flange screws (for nominal connection diameters DN 32 - DN 65)
- Including installation and operating instructions
Options
- Special versions for operating pressure PN 16
Accessories
- Screwed connection for threaded connection
- Adapter fittings
- IR-Stick
- IR-Monitor
- Stratos IF-Modules: Modbus, BACnet, CAN, LON, PLR, DP, Ext. Off, Ext. Min., SBM, Ext. Off/SBM