STRATOS


STRATOS

Design

Glandless circulation pump with threaded connection or flange connection, EC motor with automatic power adjustment.

Application

Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.

 
Type key
Example Wilo-Stratos 30/1-12
Stratos High-efficiency pump (screw-end or flange-end pump), electronically controlled
30/ Nominal connection diameter
1-12 Nominal delivery head range [m]


Special features/Product advantages

  • Maximum efficiency due to ECM technology
  • Front operation and access to terminal room, variable installation positions, display independent of position
  • Simple installation due to PN 6/PN 10 combination flanges (with DN 32 to DN 65)
  • Application possible in cooling/air-conditioning systems without ambient temperature limitation
  • Pump housing with cataphoretic (KTL) coating to prevent corrosion due to condensation formation
  • System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, CAN, LON, PLR etc.
  • Remote control via infrared interface (IR stick/IR monitor)


Technical data

  • Permissible temperature range ‐10 °C ilâ +110 °C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IPX4D
  • Screwed connection or flange connection (depending on type) Rp 1 to DN 100
  • Max. operating pressure, standard version: 6/10 bar or 6 bar (special version: 10 bar or 16 bar)


Equipment/Function

Operating modes

  • Manual control mode (n=constant)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Δp-T for temperature-controlled differential pressure (programmable via IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)


Manual functions


  • Operating mode setting
  • Differential pressure setpoint setting
  • Setting automatic setback operation
  • Pump ON/OFF setting
  • Speed setting (manual control mode)


Automatic functions


  • Variable power adjustment depending on the operating mode
  • Automatic setback operation
  • Deblocking function
  • Soft start
  • Full motor protection with integrated trip electronics


External control functions


  • "Overriding Off" control input (possible with Stratos IF-Modules)
  • "Overriding Min" control input (possible with Stratos IF-Modules)
  • "Analogue In 0 - 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)
  • "Analogue In 0 - 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)


Signal and display functions


  • Collective fault signal (potential-free NC contact)
  • Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)
  • Fault signal light
  • LC display for indication of pump data and fault codes


Data exchange

  • Infrared interface for wireless data exchange with IR-Stick/IR-Monitor
  • Modbus RTU serial digital interface for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
  • BACnet serial digital interface MS/TP Slave for connection to building automation BA via RS485 BUS system (possible with Stratos IF-Modules)
  • CAN serial digital interface for connection to building automation BA via CAN BUS system (possible with Stratos IF-Modules)
  • LON serial digital interface for connection to a LONWorks network (possible with Stratos IF-Modules)
  • WPLR serial digital interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)


Dual pump management (double pump or 2 x single pump)

  • Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): various combinations with Stratos IF-Modules (accessories) possible
  • Parallel operation (efficiency-optimised peak load activation and deactivation): various combinations with Stratos IF-Modules (accessories) possible


Equipment

  • Wrench attachment point at pump body (for threaded pipe union pumps with P2< 100 W)
  • For flange-end pumps: Flange versions
    • Standard version for DN 32 to DN 65 pumps: PN 6/10 combination flange (PN 16 flange according to EN 1092-2) for PN 6 and PN 16 counter flanges
    • Standard version for DN 80/DN 100 pumps: PN 6 flange (designed for PN 16 according to EN 1092-2) for PN 6 counter flange
    • Special version for DN 32 to DN 100 pumps: PN 16 flange (according to EN 1092-2) for PN 16 counter flange
  • Plug-in position for optional extension with Wilo-IF-Modules
  • Standard thermal insulation for heating applications


Materials

  • Pump housing: Grey cast iron with cataphoretic coating
  • Thermal insulation: Polypropylene
  • Shaft: stainless steel
  • Bearing: Carbon, metal impregnated
  • Impeller: Plastic


Scope of delivery

  • Pump
  • Including thermal insulation
  • Including seals for threaded connection
  • Incl. washers for flange screws (for nominal connection diameters DN 32 - DN 65)
  • Including installation and operating instructions


Options

  • Special versions for operating pressure PN 16


Accessories

  • Screwed connection for threaded connection
  • Adapter fittings
  • IR-Stick
  • IR-Monitor
  • Stratos IF-Modules: Modbus, BACnet, CAN, LON, PLR, DP, Ext. Off, Ext. Min., SBM, Ext. Off/SBM